CNC machine down? Speak directly to Keith
Squidex Solutions Ltd · Co. No. 10695481
Power & Environment
122 Mill & Lathe

HAAS® Alarm 122 — REGEN OVERHEAT

What it means

The regen resistor (which dissipates braking energy from the drives as heat) has gone over its temperature limit.

Common causes

  • Heavy braking pattern (lots of decel, lots of spindle stops)
  • Regen resistor partially failed
  • Cooling around the resistor blocked

What to check first

  • Let the machine cool down for 15–20 minutes
  • Check airflow around the regen resistor
  • Repeat alarms — service call to test/replace the resistor

Prevention

Cabinet maintenance is the quiet hero. A 5-minute filter clean every fortnight prevents the vast majority of cabinet-temperature and drive-temperature alarms. Replace cabinet filters at the schedule the manual specifies, not when they look clogged — by then they're already restricting airflow.

If you’re still stuck

If you’ve worked through the checks above and the alarm hasn’t cleared — or if it cleared and came back — that’s the point to call. Persistent alarms after a reset usually mean a real component fault, and pushing through them risks turning a simple repair into a bigger one. Keith covers HAAS® breakdowns across the UK with same-day phone diagnosis.

A note on this guide. Alarm wording and numbering can vary by HAAS® machine model and software revision. The descriptions here are written in plain English to help you understand what the machine is reporting and what to check first — they’re not a substitute for the official HAAS® operator manual or for a qualified service engineer’s diagnosis. Always confirm the exact alarm message on your screen and consult your machine’s documentation before attempting any repair.